The ResMed ClimateLine™ S9 heated tubing has been discontinued by ResMed as the S9 Series has reached end-of-life. Broadway Home Medical carries remaining stock. Contact either of our Wichita locations to confirm availability before ordering.
The ResMed ClimateLine™ (part #36995) is a 15mm slim heated CPAP tubing designed for use with the ResMed S9™ Series CPAP machines — specifically the S9 Escape, S9 Elite, and S9 AutoSet — equipped with an H5i™ Heated Humidifier and Climate Control. At 78" from end to end, it is 40% lighter, 20% thinner, and occupies 35% less space than conventional CPAP tubing, while delivering measured, controlled heat and humidification directly to the mask to virtually eliminate rainout. A temperature sensor at the mask end feeds the S9™ Climate Control system continuously, maintaining consistent warmth and humidity regardless of changes in room temperature. Latex-free. Works with any CPAP mask with a standard 22mm connection. Not compatible with S9 VPAP or BiLevel machines — those require the ClimateLine™ MAX. Not compatible with AirSense™ 10, AirSense™ 11, or AirCurve™ series machines. Replacement recommended every 6 months.
Compatibility Warning
This tubing is only compatible with ResMed S9™ CPAP machines (Escape, Elite, AutoSet) with an H5i™ Heated Humidifier and Climate Control. It is not compatible with S9 VPAP Auto, VPAP S, VPAP ST, or VPAP Adapt SV — those require the ClimateLine™ MAX. It is also not compatible with AirSense™ 10, AirSense™ 11, AirCurve™ 10/11, or any non-ResMed machine. If you are unsure which tubing your machine requires, contact Broadway Home Medical before ordering.
A standard CPAP tube has no heating element. When warm, humidified air from the H5i™ travels through an unheated tube on a cool night, it loses heat as it travels and condensation forms inside the tube — a condition called rainout. The result is gurgling sounds, water splashing against the mask mid-sleep, and interrupted therapy. The ClimateLine™ solves this with a built-in copper heating element that maintains the air temperature along the entire tube length. A temperature sensor at the mask end measures the actual delivered air temperature and feeds that data back to the S9™ Climate Control system, which continuously adjusts the H5i™ humidifier output to maintain the temperature you've set — regardless of changes in room temperature or humidity. What you set is what you feel, from the beginning of the night to the end. About rainout and how the ClimateLine prevents it →
The ClimateLine™ uses a 15mm internal diameter compared to the 22mm of a standard CPAP tube — 20% thinner overall and 40% lighter. In practical terms this means less tube drag on the mask as you shift position during sleep, and more flexibility when routing the tube across a pillow or over a shoulder. The slimmer profile also takes up 35% less space in a bedside table, travel bag, or suitcase. For users who travel frequently with their CPAP equipment, the ClimateLine™'s compact footprint is a meaningful improvement over conventional tubing. An optional SlimLine Tubing Wrap accessory is available separately for users who find the plastic-on-skin sensation uncomfortable during sleep. About the 15mm slim profile →
The ClimateLine™ only functions as designed when three components are present and working together: a compatible S9™ CPAP machine with Climate Control enabled, the H5i™ Heated Humidifier, and the ClimateLine™ tubing itself. All three are necessary. Without the H5i™ humidifier, the tubing has no humidity source to warm and control. Without Climate Control enabled on the machine, the temperature sensor feedback loop doesn't function and the tube heating cannot be automatically managed. If you have an S9™ machine without the H5i™ humidifier, or if your H5i™ is not set up for Climate Control mode, contact Broadway Home Medical before purchasing this tubing. About the Climate Control system requirements →
ResMed produced two ClimateLine diameters for the S9 Series. The standard ClimateLine™ (this product, 15mm, part #36995) is for CPAP machines — the S9 Escape, S9 Elite, and S9 AutoSet. The ClimateLine™ MAX (19mm) is designed for S9 VPAP and BiLevel machines, which operate at higher pressures that require a wider tube diameter to maintain adequate airflow. If you use an S9 CPAP machine, this is the right tubing. If you use an S9 VPAP Auto, VPAP S, VPAP ST, or VPAP Adapt SV, you need the ClimateLine™ MAX instead. When in doubt, check the model name on the label of your machine or call Broadway Home Medical. Comparing standard ClimateLine and ClimateLine MAX →
"The ClimateLine is the single most common upgrade we recommend to S9 CPAP users who are having rainout issues or waking up with a dry mouth or sore throat. Standard tubing can't maintain temperature across the full tube length on a cool night — this one can. The slim 15mm profile is noticeably more comfortable to sleep with than a standard bulky tube. If you're still on an S9 machine and you're not using heated tubing, it makes a real difference in how therapy feels."
Jake
General Manager & DME Expert — Broadway Home Medical, Wichita KS
| Part Number | 36995 |
|---|---|
| Tubing Type | Heated — 15mm slim diameter |
| Length | 78" end to end (approx. 6.5 feet) |
| Internal Diameter | 15mm |
| Temperature Sensor | Yes — at mask end |
| Heating Element | Internal heated coil |
| Oxygen Port | No — for O₂ port version see ClimateLine™ MAX OXY (#36996) |
| Material | Latex-free |
| Mask Compatibility | Any mask with standard 22mm connection cuff |
| Compatible Machines | ResMed S9 Escape, S9 Elite, S9 AutoSet — with H5i Humidifier + Climate Control |
| Not Compatible With | S9 VPAP Auto / S / ST / Adapt SV, AirSense 10/11, AirCurve 10/11, non-ResMed machines |
| Replacement Interval | Every 6 months recommended |
| Washable | Yes — can be submerged; must be completely dry before use |
Common questions from customers at Broadway Home Medical about the S9 ClimateLine heated tubing.
Rainout is condensation that forms inside the CPAP tube when warm, humid air from the humidifier cools as it travels through an unheated tube toward the mask. It produces a gurgling noise, occasional water hitting the inside of the mask during sleep, and can wake you up or interrupt therapy. The ClimateLine™ prevents rainout by heating the tube along its entire length with an internal heated coil, keeping the air temperature consistent from the humidifier to the mask. The mask-end temperature sensor feeds real-time temperature data back to the S9 machine's Climate Control system, which adjusts the H5i humidifier continuously to maintain your set temperature throughout the night.
Yes. The ClimateLine™ requires three components to function as designed: a compatible S9 CPAP machine with Climate Control, the H5i™ Heated Humidifier, and the ClimateLine tubing. The tubing's sensor communicates with the Climate Control system, which controls the H5i's output. Without the H5i, there is no humidity source for the ClimateLine to manage. Without Climate Control enabled, the feedback loop doesn't work and tube temperature cannot be automatically regulated. The ClimateLine does not provide heated humidification by itself — it is part of a system.
The standard ClimateLine™ (this product, part #36995) has a 15mm internal diameter and is designed for S9 CPAP machines — the Escape, Elite, and AutoSet. The ClimateLine™ MAX has a 19mm internal diameter and is designed for S9 VPAP and BiLevel machines, which require the wider diameter to support higher operating pressures. If you use a standard CPAP machine, this tubing is correct. If you use a VPAP Auto, VPAP S, VPAP ST, or VPAP Adapt SV, you need the ClimateLine MAX. Using the wrong diameter tubing for your machine type can affect therapy performance.
No — the S9 CPAP machines are designed to operate effectively with the 15mm ClimateLine tubing at normal CPAP pressure ranges. The thinner diameter is appropriate for the pressure levels these machines deliver. The main user-facing benefits are reduced weight and bulk, less tube drag on the mask, and greater flexibility when moving during sleep. The slimmer profile does not reduce humidity delivery or heating effectiveness — the Climate Control system compensates for tube geometry automatically.
Yes — the ClimateLine™ works with any CPAP mask that uses a standard 22mm connection cuff. This covers the vast majority of CPAP masks on the market. The mask-side connection is standard; the machine-side connection is specific to the S9 Series, which is why the tubing cannot be used on AirSense or AirCurve machines with different ports.
Technically yes, but it is strongly not recommended. Heated tubing draws significant additional power — it can reduce CPAP battery runtime by 70–80% compared to running the machine without heated tubing and humidification. If you rely on a battery for camping, power outages, or travel, turning off the ClimateLine and the H5i humidifier before switching to battery power will dramatically extend how long the battery lasts. Standard unheated tubing should be used for battery-powered operation when runtime is critical.
Daily: disconnect the tubing from the machine and mask and hang to air dry in a clean area away from direct sunlight. Weekly: wash with warm water and a mild detergent. The ClimateLine can be submerged in water for cleaning — rinse thoroughly after washing, then hang to air dry completely before reconnecting. The tube must be completely dry before use. Do not use harsh cleaning agents, bleach, or dry in direct sunlight or with heat.
Replacement every 6 months is recommended. The internal heating element and temperature sensor degrade gradually with use, which can reduce the accuracy of Climate Control and the effectiveness of rainout prevention over time. Tubing that has been in use for more than 6 months may also be difficult to keep fully clean. Given that the S9 ClimateLine is discontinued, picking up a spare while stock is available at Broadway Home Medical is worth considering.
The ResMed S9 ClimateLine is available at Broadway Home Medical while stock lasts. Stop by or call either of our Wichita locations to confirm availability. If you're unsure whether this is the correct tubing for your specific S9 machine model, our staff can verify before you order.
The ResMed ClimateLine™ is designed exclusively for use with ResMed S9™ Series CPAP machines (Escape, Elite, AutoSet) equipped with an H5i™ Heated Humidifier and Climate Control. Not compatible with S9 VPAP series, AirSense™ 10, AirSense™ 11, AirCurve™ 10/11, or non-ResMed machines. CPAP therapy equipment is typically dispensed pursuant to a physician prescription. Heated tubing significantly reduces CPAP battery runtime — disable heated tubing and humidification when operating on battery power. Replace every 6 months or as directed by your care provider. Product has been discontinued by ResMed — availability subject to remaining stock. Specifications subject to change without notice.