TUB06HS10 Heated CPAP Tube/Adapter for Resmed AirSense 10

$36.00

TUB06HS10
Available By
Shipping or Special Order Only* These Orders May Have Additional Lead Time. See Special Order Terms for more information or Contact Us

Product description

Sunset TUB06HS10 Heated CPAP Tube with adapter for ResMed AirSense 10

Sunset Heated CPAP Tube and Adapter for ResMed AirSense™ 10 (TUB06HS10)

The Sunset TUB06HS10 is a heated CPAP tube and adapter kit that lets the Sunset Heated CPAP Tube work with the ResMed AirSense™ 10. The patent-pending adapter clicks onto the AirSense 10's air outlet port and carries the heating connection, so the machine's climate control keeps working to prevent rainout and the prescribed pressure is maintained. It's an easy-to-use, cost-effective alternative to the OEM heated tube, and it fits into an existing CPAP cleaning routine without any change in process. 6 ft. (1.83 m) long with a 15 mm internal diameter. Flow resistance of 0.1 kPa or less at 60 L/min. Single-patient reuse, latex-free, and not made with phthalates. Replace every 3 months, or sooner if damaged. Compatible with the ResMed AirSense 10 only. The adapter is also sold separately as TUB06HS10-ADAPT.

Compatibility

This tube and adapter are designed for the ResMed AirSense™ 10. They are not compatible with the AirSense 11, AirCurve series, ResMed S9 series, or machines from other manufacturers. The heated tube requires a CPAP machine with a heated humidifier to deliver its intended benefit. If you aren't sure which machine you have, contact Broadway Home Medical before ordering.

What the Adapter Does

Heated tubing uses a wire inside the tube to keep the air warm along its full length, which prevents the condensation known as rainout. The catch is that each machine manufacturer uses its own proprietary connection to power that heating wire, so a heated tube built for one machine generally can't be used on another. The Sunset adapter solves that for the AirSense 10. It aligns with the machine's air outlet port and seats a connector lead into the mating connector at the top of the port, clicking into place on both sides. The Sunset Heated CPAP Tube then connects to the adapter rather than directly to the machine. The result is a working heated-tube setup on an AirSense 10 using Sunset tubing instead of the OEM part. How the adapter connects →

Sunset TUB06HS10-ADAPT heated CPAP tube adapter for ResMed AirSense 10, front
Sunset heated CPAP tube adapter attached to a ResMed AirSense 10 machine

Climate Control and Prescribed Pressure Are Preserved

Two things matter most when substituting any component into a CPAP circuit: whether therapy pressure is still delivered as prescribed, and whether the machine's humidity and temperature management still functions. Sunset designed the TUB06HS10 to maintain prescribed pressure and to preserve the function of the AirSense 10's climate control so it continues to prevent rainout. The tube's flow resistance is rated at 0.1 kPa or less at 60 L/min, and the tube meets ISO 5367, ISO 80601-2-70, and ISO 80601-2-74 — the same standards families that govern breathing tubes, sleep apnea therapy equipment, and respiratory humidifying equipment. About pressure and climate control →

Fits Your Existing Cleaning Routine

The tube and adapter are cleaned the same way as standard CPAP tubing, with no extra steps and no special equipment. Clean before first use and daily during use: disconnect the tube and adapter, rinse inside and out with cold tap water, wash gently in warm water with a mild unscented liquid dish soap using a soft bristle brush, rinse thoroughly, tap the cuffs downward to shed excess water, and hang with the cuffs pointed toward the floor to air dry completely. Do not use harsh soaps, detergents, solvents, or alcohol, and do not clean in a dishwasher, ultrasonic cleaner, or any other cleaning device. Never use a brush or other object inside the tube itself, and never use an oven, fan, or heater to speed drying. Only reuse once fully dry. Full cleaning instructions →

"Heated tubing is the fix for rainout, and rainout is one of the most common reasons people stop using their machine. The problem has always been that you're locked into the manufacturer's tube. This adapter opens up a less expensive option for AirSense 10 users while keeping the climate control working the way it should. The only thing I'd stress is the replacement schedule — three months, same as any heated tube. Don't stretch it."

Jake

General Manager & DME Expert — Broadway Home Medical, Wichita KS

Replace Every 3 Months

Sunset specifies replacement of both the tube and the adapter every 3 months, or according to your provider's recommended schedule. The IFU sets a hard maximum of 90 days of use — beyond that, the manufacturer warns that therapy quality can be affected. Replace immediately at any point if the tube is damaged, leaking, kinked, torn, has exposed heating wires, or stops functioning. Inspect the tube daily for holes, deformation, or other damage as part of your normal routine. Most Medicare and private insurance plans cover CPAP tubing replacement on a defined schedule; Broadway Home Medical can check your coverage. About the replacement schedule →

TUB06HS10 Features at a Glance

  • Adapts the Sunset Heated CPAP Tube for use with the ResMed AirSense 10
  • Easy-to-use, cost-effective alternative to the OEM heated tube
  • Patent-pending adapter design
  • Maintains prescribed pressure
  • Preserves climate control function to prevent rainout
  • Fits seamlessly into an existing CPAP cleaning routine
  • 6 ft. (1.83 m) length
  • 15 mm internal diameter
  • Flow resistance 0.1 kPa or less at 60 L/min
  • Squeeze-release tabs on both the tube cuff and the adapter
  • Single-patient reuse — home and clinical settings
  • May be used with non-invasive ventilation for adult patients
  • Not made with natural rubber latex
  • Not made with phthalates (PHT/DEHP)
  • IP22 ingress protection
  • Type BF applied part
  • Replace every 3 months (90-day maximum)
  • Adapter also available separately as TUB06HS10-ADAPT

Specifications

SKU — Tube and Adapter Kit TUB06HS10
SKU — Adapter Only TUB06HS10-ADAPT
Compatible CPAP Machine ResMed AirSense 10 only
Tube Length 6 ft. (1.83 m)
Internal Diameter 15 mm
Flow Resistance at 60 L/min ≤ 0.1 kPa
Ingress Protection IP22 — protected from objects over 12 mm and water spray within 15° of vertical
Electrical 3.3 Vdc, max. 5 A
Humidifier Classification Class 2 (ISO 80601-2-74)
Electrical Shock Protection Type BF applied part
Standards Compliance ISO 5367:2014, ISO 80601-2-70:2015, ISO 80601-2-74:2017, IEC 60601-1, EN 60601-1-2
Material Safety Not made with natural rubber latex; not made with phthalates (PHT/DEHP)
Reuse Single patient, multiple use
Replacement Interval Every 3 months (90-day maximum)
Operating Temperature 41°F–104°F (5°C–40°C)
Operating Humidity 5%–95% relative humidity
Storage Temperature -13°F to 140°F (-25°C to 60°C)
MRI Safety MR Unsafe — keep outside the MRI scanner room
Warranty 30 days under normal operating conditions (based on 8 hours daily use)

Frequently Asked Questions — Sunset TUB06HS10

Common questions from customers at Broadway Home Medical about the Sunset heated tube and adapter.

How does the adapter connect to my AirSense 10?

Align the adapter with the air outlet port on the AirSense 10 and place the connector lead into the mating connector at the top of the port. Press until the tabs on each side of the connector click into place. Then connect the tube's adapter connector cuff to the adapter, and the mask-end cuff to your mask. To disconnect, lightly squeeze the release tabs on the side of the tube cuff to remove the tube, then squeeze the release tabs on the adapter to remove it from the machine. Always handle the tubing by the cuff — never pull or stretch the tube itself, as that can cause circuit leaks.

Will this affect my prescribed pressure or my machine's climate control?

Sunset designed the TUB06HS10 to maintain prescribed pressure and to preserve the function of the AirSense 10's climate control so it continues to prevent rainout. The tube is rated at a flow resistance of 0.1 kPa or less at 60 L/min and meets ISO 5367, ISO 80601-2-70, and ISO 80601-2-74. If you notice any change in how your therapy feels after switching tubing, contact your prescribing physician or respiratory therapist.

What is rainout and how does heated tubing prevent it?

Rainout is condensation that forms inside the tube when warm, humidified air from the humidifier cools on its way to the mask. It causes a gurgling sound, water splashing into the mask during sleep, and interrupted therapy. A heated tube has a heating wire that keeps the air warm along the full length of the tube, so the air never cools enough for condensation to form. The heated tube works together with the machine's heated humidifier — it does not provide humidification by itself.

Will this work with my AirSense 11 or another CPAP machine?

No. The TUB06HS10 adapter is designed specifically for the ResMed AirSense 10 air outlet port. It is not compatible with the AirSense 11, the AirCurve series, the older ResMed S9 series, or machines from other manufacturers, because each uses a different heated-tube connection. If you have a machine other than the AirSense 10, contact Broadway Home Medical and we can identify the correct heated tubing for your setup.

How often do I replace the tube and adapter?

Sunset specifies replacement of both the tube and the adapter every 3 months, or according to your provider's recommended schedule. The manufacturer sets a hard maximum of 90 days of use. Replace immediately if the tube is damaged, leaking, kinked, torn, shows exposed heating wires, or stops working — do not attempt to repair it yourself. Inspect the tube daily for holes, deformation, or other damage. Many insurance plans cover CPAP tubing replacement on a set schedule; we can check your coverage.

How do I clean the heated tube and adapter?

Clean before first use and daily during use. Disconnect the tube from the adapter and mask, and the adapter from the machine. Rinse inside and out with cold tap water, then wash gently in warm water with a mild unscented liquid dish soap, using a soft bristle brush on the exterior. Rinse thoroughly to remove all soap residue, tap the cuffs downward to shed excess water, and hang the tube with the cuffs pointing toward the floor to air dry completely. Do not use harsh soaps, detergents, solvents, or alcohol. Do not clean in a dishwasher, ultrasonic cleaner, or any other cleaning device. Do not use a brush or any object inside the tube, and do not use an oven, fan, or heater to dry it. Only reuse when fully dry.

How is this different from the ResMed OEM heated tube?

The TUB06HS10 is a third-party alternative from Sunset Healthcare Solutions rather than a ResMed part. It uses a patent-pending adapter to bridge the Sunset Heated CPAP Tube to the AirSense 10's heated-tube connection, which is what makes the substitution possible. Sunset positions it as a cost-effective alternative that maintains prescribed pressure and preserves climate control function. The tube is 6 ft. with a 15 mm internal diameter. If you have questions about whether a non-OEM tube is appropriate for your therapy, talk with your prescribing physician or respiratory therapist, or ask our staff.

Can I buy just the adapter?

Yes. Sunset sells the adapter separately under part number TUB06HS10-ADAPT. That said, the adapter carries the same 3-month replacement schedule as the tube, so most users replace both together. The TUB06HS10 kit includes both the heated tube and the adapter. Contact Broadway Home Medical for current availability of either option.

Where can I get the Sunset heated CPAP tube in Wichita, Kansas?

The Sunset TUB06HS10 heated CPAP tube and adapter is available at Broadway Home Medical, Wichita's largest DME store. Stop by either of our two locations or call us. If you're unsure whether your machine is an AirSense 10, bring it in or send us a photo of the label and we can confirm before you order. We can also check your insurance coverage for CPAP tubing replacement.

The Sunset Heated CPAP Tube and Adapter is a heated wire breathing tube intended to provide warmed and/or humidified breathing gases before they enter a patient's airway, indicated for single-patient reuse in home and clinical settings and for use with non-invasive ventilation in adult patients. Compatible with the ResMed AirSense 10 only. Read the instructions for use before first use and retain for reference. Do not sterilize. Do not use on multiple patients. Replace after a maximum of 90 days of use, or immediately if damaged. MR Unsafe — keep outside the MRI scanner room. Do not operate near other heat sources such as lamps or electric blankets. CPAP supplies are typically dispensed pursuant to a physician prescription; consult your prescribing physician or respiratory therapist before changing components in your CPAP circuit. Warranty is 30 days under normal operating conditions based on 8 hours of daily use. Specifications from Sunset IFU-00148 REV 1.03 and subject to change without notice. ResMed and AirSense are trademarks of ResMed Inc. Sunset Healthcare Solutions is not affiliated with ResMed Inc. Product information: https://sunsethcs.com/product/tub06hs10-heated-cpap-tube-adapter-for-resmed-airsense-10/